the right connection
Diagnostic Coupling, Model : MMC
Ref. No : H04312, Release June 2008 (Dimensions in mm)
Stud end
threads
Sealin
details
Workin
Pressure
Ød1iHSHS
ISO 228 - G 1/8 Elastomeric seal 400 bar 14 8 38 17 38 14
ISO 228 - G 1/4 (DIN 3852) 630 bar 19 10 35 19 29 19
ISO 228 - G 3/8 630 bar 22 10 35 22 29 22
M8 x 1.0 O-Ring (ISO 6149) 250 bar 12 8.5 40 17 38 14
M10 x 1.0 Elastomeric seal 14 8.5 40 17 38 14
(DIN 3852) 9.5
M12 x 1.5 630 bar 17 10.0 35 17 29 17
11.0
M14 x 1.5 O-Ring (ISO 6149) 19 10.0 35 19 29 19
11.5
M16 x 1.5 22 10.0 35 22 29 22
12.5
7/16"-20 UNF O-Ring (SAE J514) 630 bar 14.1 9.0 35 17 30 17
9/16"-18 UNF 17.3 10.0 35 19 29 19
1/8 NPTF Self sealing threads 400 bar -- 9.7 35 17 30 14
1/4 NPTF -- 14.2 35 17 29 14
ISO 7/1 - R 1/8 Sealing by 400 bar -- 7.5 35 17 32 14
ISO 7/1 - R 1/4
su
a
e
o
n
n
solutions
630 bar -- 11.0 35 17 29 14
For 1615
and 1620 For 1215
Copyrights
©
2008 hyloc hydrotechnic pvt. ltd. All rights reserved Engineering Datasheet, Page 1/2
Description
Unit Dimensions
Diagnostic Couplings are intended to provide facility to access
system pressure for the purpose of pressure measurement.
For transmitting pressure through these couplings to the measuring
devices, no special tools are needed. These couplings can be connected
by hand even at rated pressure.
These couplings are equipped with protective caps to avoid ingress of
foreign particles, when the couplings are not in use. This is also a Safety
device against vibration.
These couplings also can be used for purging air from the system.
Working Pressure 630 bar (9000 PSI) according to ISO 15171-2
Section
For M16 x 2.0 (1620), M16 x 1.5 (1615)
and for special thread at Hose end. ( 1215 )
'S' A / F
H
Ø19
i
Ød1
G
*
Marked dimensions are for stud
ends with O' Ring sealing
Hydraulic Symbol
*
*
*
*